SVG STATCOM Line
Cascaded medium-voltage static var generator connecting directly at distribution voltage. Response to 5 ms, 20-year design life, MTBF above 75,000 hours, with reactive, harmonic and negative sequence compensation modes. Every power unit is full-load tested before shipment.
- Response time up to 5 ms
- Rated voltages 6 kV, 10 kV, 27.5 kV, 35 kV and 55 kV, 1-ph or 3-ph, 50 Hz
- Designed service time 20 years; MTBF > 75000 hours; MTTR < 5 minutes
- Reactive power, harmonic current and negative sequence compensation, or comprehensive compensation
- 100% power unit full load and high temperature aging test; complete set full load test up to 200 Mvar
- Air cooling or water cooling; fibre optic HV isolation
Overview
The SVG Statcom Line is a chain structured static var generator (static synchronous compensator) that acts as a variable reactive power supply to compensate for variation of reactive power in the load. Each power unit has an identical structure and performance, which the brochure credits for the reliability, flexibility and availability of the system.
Main functions include improving power transmission stability, maintaining the receiving-end voltage level, compensating reactive power and improving power factor, harmonic compensation, reducing voltage fluctuation and flicker, and reducing 3-ph unbalance.
SVG Statcoms are applied in power transmission, electric railways, metallurgical, oil and gas, and wind power industries. Every power unit is full load tested and aged at high temperature, and complete sets are full load tested up to 200 Mvar.
Specifications
Electrical
- Rated voltage
- 1-ph / 3-ph, 50 Hz; 6 kV / 10 kV / 27.5 kV / 35 kV / 55 kV
- Power factor
- > 0.95
- Harmonics
- In accordance with related IEEE Standard
- Power semiconductor
- IGBT
- Structure
- Chain structured; modularised design facilitates ease of transportation and site installation
- HV isolation
- Fibre optic communication
- Power supply for control
- 380 VAC or 220 VDC
Performance
- Response time
- Up to 5 ms
- Designed service time
- 20 years
- MTBF
- > 75000 hours
- MTTR
- < 5 minutes
- Compensation functions
- Reactive power compensation, harmonic current compensation, negative sequence compensation and comprehensive compensation
Capacity by voltage (product selection)
- 6 kV, direct connection
- < 7.8 Mvar (star); < 13.5 Mvar (delta); air or water cooling
- 10 kV, direct connection
- < 13 Mvar (star); < 22.5 Mvar (delta); air or water cooling
- 27.5 kV, direct connection
- 3.5 ~ 18 Mvar (27.5 kV single phase); < 55 Mvar (27.5 kV delta); air or water cooling
- 27.5 kV, step down
- < 3.5 Mvar (6 kV single phase); air or water cooling
- 35 kV, direct connection
- 7 ~ 45 Mvar (star); < 29.5 Mvar (delta); air or water cooling
Control & protection
- Control mode
- Instantaneous current test; PWM current tracing; DC current close loop control; voltage balancing technology on DC side
- Control chip
- Advanced DSP; site programmable array
- Protocol
- Modbus
- Protections
- Over-current, short-circuit, grounding, over / under-voltage, open phase, over-temperature, control power supply fault and communication fault
- Display
- Network current / volt, load current, compensation current, active and reactive power and PF
Cooling & enclosure
- Cooling
- Air cooling / water cooling
- Protection class
- IP 20 (customisation available)
- Installation environment
- Indoor, free of corrosive or explosive gas
- Ambient temperature
- 0 – 40 °C
- Humidity
- < 90%, non-condensing
- Elevation
- ≤ 1000 m above sea level (customisation available)
- Storage / transportation temperature
- -40 °C to 70 °C
Let's Solve Your Power Challenge.
Send an enquiry to our engineering team. We'll help you identify risks and uncover efficiency opportunities.
Renewable Energy & Drives
5325 S Moorland RdNew Berlin, WI 53151United States
Severn Drives & Energy
Units 2 & 3, Kingsley Business ParkNew Road, Kibworth BeauchampLeicestershire, LE8 0LEUnited Kingdom
Send an enquiry
Fill out the form below and we'll be in touch.