We design, build and support the critical power infrastructure that keeps your operations running, from the first study to the last spare part.
We do not believe in one-size-fits-all. Real power resilience comes from understanding your operating reality, from the first feasibility study through to the tenth year of monitoring. Our team integrates with yours to deliver solutions that are not just specified, but optimized for performance, safety and a long lifecycle.
Five product families, each with a full technical page: ratings, specifications, applications and downloadable literature.
UPS SYSTEMSModular low-voltage UPS from 50 kW to 4.8 MW, and medium-voltage PureWave UPS to 22.5 MW at 5–25 kV. Both protect the whole facility, not one row of racks.
ENERGY STORAGEGrid-forming storage customised to any size, with standard configurations from 365 kWh cabinets to 50 MWh medium-voltage blocks. Cascaded topology, liquid cooled, sub-5 ms response, no station transformer.
REACTIVE POWERThree-level IGBT STATCOM and MV SVG customised to any size, with standard platforms to ±3600 kvar per system and 6–55 kV. Response from 5 ms, with fault ride-through, harmonic and negative sequence compensation.
PRIVATE WIREA controlled converter interface that sells local generation directly to local demand, islanded or grid-parallel, built to the capacity the project requires with a G99 fault-ride-through variant.
Consultancy, commissioning, maintenance and monitoring. All offered standalone, not only as an attachment to an equipment order.
CONSULTANCYGrid-code compliance, protection coordination and power system studies, modelled in DIgSILENT PowerFactory and signed off by chartered engineers.
FIELD SERVICESCommissioning, FAT/SAT, preventive maintenance, repairs and refurbishment, including legacy PureWave and DSTATCOM fleets the original manufacturer no longer supports.
MONITORINGContinuous health monitoring, predictive fault analytics and secure remote diagnostics, so most faults are diagnosed before anyone gets in a van.
Measurement and modeling before specification. Harmonic assessment, fault level, protection grading, load profile: whatever the actual constraint turns out to be.
A sizing recommendation our own engineering team has to deliver against, with the assumptions stated on the page so a reviewer can accept or challenge them.
Factory assembly and full-load testing before shipment, so site work is a connection rather than a construction project.
FAT, SAT, commissioning, then monitoring and scheduled maintenance for as long as the asset runs, including after the product line is retired.
Every sector fails differently. These pages describe what actually breaks in yours, and what we deploy against it.
Tell us what is limiting you: a connection offer, a penalty charge, a trip nobody can explain, a piece of equipment nobody will support. We will tell you what we would measure first, and whether we are actually the right people for it.
Connect with our engineering team for a technical consultation. We'll help you identify risks and uncover efficiency opportunities.
5325 S Moorland RdNew Berlin, WI 53151United States
Units 2 & 3, Kingsley Business ParkNew Road, Kibworth BeauchampLeicestershire, LE8 0LEUnited Kingdom
Fill out the form below and we'll be in touch.