    PureWave® SMS Storage Management System

    Grid interface for energy storage systems

    Storage management and power conversion platform for renewable integration, energy time-shifting, capacity firming and ancillary services. Documentation and support available from RE&D, and available to build to order.

    • Converts ac power to dc to charge the battery and controls discharge into the electrical system
    • Eight selectable modes including islanding, peak shaving, frequency regulation and power smoothing
    • Automatic islanding on utility over/under-voltage or over/under-frequency events
    • Can provide leading or lagging vars
    • Controlled locally through an HMI computer or remotely through a SCADA interface
    • Supplied in a container with separate inverter room and control room

    Overview

    The PureWave SMS is a fast-response power controller that converts ac power to dc to charge an energy storage system and controls the discharge of the battery into the electrical system. This lets a wide variety of applications be powered by stored energy when primary power from the utility is not available.

    The PCS and batteries are connected in parallel to the distribution feeder through a three-phase transformer. Batteries can be charged during off-peak times and discharged during peak demand, and the system can supply leading or lagging vars. On a utility disturbance it can automatically open the islanding breaker and re-energize the load in voltage-source mode.

    Specifications

    Operating modes

    Modes
    Islanding, Direct Power Control, Frequency Regulation, Power Smoothing, Power Scheduling, Peak Shaving, Vac Regulation using Vars, Direct Var Control
    System states
    8: Program Reset, Inhibit, Trip Offline, Ready, Voltage Source Run, Current Source Run, Open Input Switch, Close Input Switch
    Reset types
    Manual, Auto, Self
    Return to utility after disturbance
    Adjustable time delay, 5 minutes default

    Control & communications

    Local interface
    HMI industrial PC (Linux operating system) on master control rack
    Remote control
    SCADA interface (DNP points)
    HMI access levels
    Level 1 observe, Level 2 control
    Remote HMI connection
    Electronic certificates only
    Local/Remote switch
    Switches control between SCADA and HMI
    Emergency stop
    INVERTER STOP button, typically at each container man door

    Configuration

    Enclosure
    Container with inverter room and control room
    PCS enclosure sections
    Ac section, left and right inverter bays, left and right dc bays
    Inverter bay contents
    Three-phase dc-ac inverter, dc-dc converter (chopper), ac filter inductor
    Dc bay contents
    Two dc circuit breakers and dc interface control panel
    Utility connection
    Through a three-phase transformer
    Cooling
    Fans on ac and dc bays; blower with variable frequency drives on inverter bays

    Standards

    Grid protection settings
    Over/under-voltage and over/under-frequency alarms used to comply with IEEE 1547; default settings according to IEEE 1547
    GET IN TOUCH

    Let's Solve Your Power Challenge.

    Connect with our engineering team for a technical consultation. We'll help you identify risks and uncover efficiency opportunities.

    North America

    Renewable Energy & Drives

    5325 S Moorland RdNew Berlin, WI 53151United States

    UK & Europe

    Severn Drives & Energy

    Units 2 & 3, Kingsley Business ParkNew Road, Kibworth BeauchampLeicestershire, LE8 0LEUnited Kingdom

    Start Your Consultation

    Fill out the form below and we'll be in touch.